Filter Constant K2

(Trunking Wide, Filter Constants)

HGDefinitionMob%26Port.jpg

Selects the K2 Filter Constant value, which is used when 8 to 16 seconds elapse between Received Signal Strength Indication (RSSI) samples (see also the RSSI Thresholds fields). The selected Filter Constant K2 value is used by the Filter Threshold Constant T2. This selection can apply for all Trunking Systems and therefore to all Trunking Personalities.

HGWarning.jpg

 

Modifications of Filter Constants should only be performed by a Motorola Field Technical Representative.

HGAccessedOnly.jpg

When the radio is model / option capable.

HGSelections.jpg

Minimum

Maximum

0

9

IconSmallNote.png

The RSSI filter has the following characteristic Filter Val. = (Filter Val. * K + Current Reading * (10 - K)) / 10 where the domain of K is {K: K = K1, K2, K3} and 0 (no filter) <= K3 <= K2 <= K1 <= 9 (heavily damped filter).

In a SmartZone system, the constants K1, K2, and K3 are designed to reduce filter damping as time between sampling increases.

  • K1 is used when less than 8 seconds elapses between RSSI samples

  • K2 is used when 8 to 16 seconds elapse between RSSI samples

  • K3 is used when more than 16 seconds elapse between RSSI samples

GoArrow.jpg

Go to the Filter Constants Page